Inconsistent Path Accuracy - ABB OmniCore C30 Product Manual

Hide thumbs Also See for OmniCore C30:
Table of Contents

Advertisement

6.2.9 Inconsistent path accuracy

Description
The path of the robot TCP is not consistent. It varies from time to time, and is
sometimes accompanied by noise emerging from bearings, gearboxes, or other
locations.
Possible causes
The symptom can be caused by (the causes are listed in order of probability):
Recommended working procedure
The path accuracy depends on many factors. The following table describes the
most common causes of problems with the path accuracy. Depending on your
installation, the recommended working procedure is to work step by step, starting
with the step that seems most plausible given your circumstances.
1
2
3
4
5
6
7
Product manual - OmniCore C30
3HAC060860-001 Revision: P
Robot not calibrated correctly.
Robot TCP not correctly defined.
Parallel bar damaged (applies to robots fitted with parallel bars only).
Mechanical joint between motor and gearbox damaged. This often causes
noise to be emitted from the faulty motor.
Bearings damaged or worn (especially if the path inconsistency is coupled
with clicking or grinding noises from one or more bearings).
The wrong robot type may be connected to the controller.
The brakes may not be releasing correctly.
Action
Study the path of the robot in motion, to
find if an external force, for example, an
external cable package, is colliding with
or restricting the movement of the robot.
In high temperature environments, the
material in the robot can expand, thereby
causing inconsistent path accuracy.
Make sure the robot tool and work object
are correctly defined.
Check the positions of the revolution
counters.
If required, re-calibrate the robot axes.
If you hear noise that has not been there
before, locate the source to define if a
motor or bearing is faulty.
Study the path of the robot TCP to estab-
lish which axis, and thus which motor,
may be faulty.
Check the trueness of the parallel bar
(applies to robots fitted with parallel bars
only).
© Copyright 2019-2022 ABB. All rights reserved.
6 Troubleshooting
6.2.9 Inconsistent path accuracy
Note
Remove the obstacles.
Improve the ventilation around the robot.
How to define these are described in Oper-
ating manual - OmniCore.
Update if required.
How to calibrate the robot is described in
the product manual for the robot.
Replace the faulty motor, gearbox, or bearing
as specified in the product manual for the
robot.
Replace the faulty parallel bar as specified
in the product manual for the robot.
Continues on next page