Function Tests; Function Test Of Emergency Stop - ABB OmniCore C30 Product Manual

Hide thumbs Also See for OmniCore C30:
Table of Contents

Advertisement

4 Maintenance

4.5.1 Function test of emergency stop

4.5 Function tests

4.5.1 Function test of emergency stop
Overview
Validate the function of the FlexPendant emergency stop device.
Performing the function test
1
2
3
4
5
212
Note
Also perform the test for any additional emergency stop devices.
Action
Make a visual inspection of the emergency
stop device to make sure it is not physically
damaged.
Pull and rotate the emergency stop device
clockwise to verify that it is not pressed in.
Power on the robot.
Press the emergency stop device on the
FlexPendant.
Note
If the event message 20223 Emergency
stop conflict appears in the event log, or
the event message 10013 Emergency stop
state (and 90518 Safety controller Emer-
gency stop triggered for collaborative ro-
bots) does not appear, then the test has
failed and the root cause of the failure must
be found.
Release the emergency stop device to re-
set the emergency stop state.
© Copyright 2019-2022 ABB. All rights reserved.
Note
If any damage is found on the emergency
stop device, it must be replaced.
The test is passed if the event message
10013 Emergency stop state appears in
the event log.
Note
For collaborative robots, the event mes-
sage 90518 Safety controller Emergency
stop triggered appears by default. The
message 10013 Emergency stop state is
also available in the event log.
Product manual - OmniCore C30
3HAC060860-001 Revision: P