ABB OmniCore C30 Product Manual page 556

Hide thumbs Also See for OmniCore C30:
Table of Contents

Advertisement

6 Troubleshooting
6.3.11 Troubleshooting the robot signal exchange proxy
Continued
LEDs
The illustration below shows the LEDs on the robot signal exchange proxy:
xx1700001886
MS
Continues on next page
556
Description
Status LED (bi-colored green/red) for the
robot signal exchange proxy.
Note
The status LED light stays on for a long
time after power to the controller is gone.
This is due to the capacitors in the robot
signal exchange proxy.
© Copyright 2019-2022 ABB. All rights reserved.
Significance
The status indicator LED can be used to
identify the following status during star-
tup/power on:
Red, solid: Default when power is
available.
Red, flashing: Power on self-test
ongoing, operating system is
loading.
Green, flashing: Application is
loaded and waiting for communic-
ation.
Green, solid: Module is operation-
al.
If the LED does not turn steady green
after 30-60 sec, the status LED can be
used to identify the following issues:
No color: Power to the robot signal
exchange proxy is missing.
Red, solid: Internal error.
Red, flashing: Firmware error or
self-test failure.
Green, flashing: Communication
error to another module.
Product manual - OmniCore C30