3 Installation and commissioning
3.8.3 Installing Integrated Vision
Continued
Spare part
Integr Vision power cable
Integr Vision ethernet cable
Required tools and equipment
Equipment
Standard toolkit
ESD protective wrist band
Required documents
Document
Circuit diagram - OmniCore C30,
Circuit diagram - OmniCore C30
for IRB 14050, Circuit dia-
gram - OmniCore C30 for CRB
15000
Application manual - Integrated
Vision
Installing Integrated Vision camera connections
1
2
3
4
Continues on next page
198
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Fit the cameras to the mounting rail (not
supplied from ABB).
Connect the Ethernet cable from the
camera to any of the LAN connectors on
the main computer or the Ethernet
switch.
© Copyright 2019-2022 ABB. All rights reserved.
Article number
Note
3HAC051753-003
3HAC051736-003
Article number
Note
-
Content is defined in section
Standard toolkit for controller on
page
-
Article number
Note
3HAC059896-009,
3HAC063898-009,
3HAC072448-009
3HAC067707-001
Note/Illustration
Location of wrist strap button:
xx1800000683
Product manual - OmniCore C30
570.
3HAC060860-001 Revision: P

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents