5 Repair
5.2.10 Replacing the power unit
Continued
2
3
Removing the power unit
1
2
31 Not available for CRB 15000 controller.
32 Only used for CRB 15000 controller.
33 Not available for CRB 15000 controller.
34 Only used for CRB 15000 controller.
Continues on next page
360
Action
Remove the screws on the bracket.
Loosen the screw and disconnect:
SMB - K6.X4, K6.X5
Action
Disconnect:
A1.X13 - K2.X10
A1.X9 - K2.X4
31
A1.X4 - T4.X5
32
A1.X4 - X1
A1.X5 - T4.X1
A1.X12 - T4.X3
A1.X1 - Incoming mains (X0)
33
A1.X6 - T2.X1
34
A1.X6 - X107
(Option) A1.X7 - T5.X1
Open the velcro strap for the main har-
ness. Lift the harness gently out to make
room for the power unit to be removed.
© Copyright 2019-2022 ABB. All rights reserved.
Note/Illustration
xx1900001200
Note/Illustration
Product manual - OmniCore C30
3HAC060860-001 Revision: P