6 Troubleshooting
6.3.8 Troubleshooting the axis computer
Continued
Description
Axis computer
status LED
Ethernet LED
546
Significance
Normal sequence during startup:
1 Red, solid: Default at power-up.
2 Red, flashing: Establish connection to main computer and load
program to axis computer.
3 Green, flashing: Start-up of axis computer program and connect
peripheral units.
4 Green, solid: Start-up sequence ready. Application is running.
The following indicates errors:
No color: No power to axis computer or internal error (hard-
ware/firmware).
Red, solid: The axis computer has failed to initialize basic hard-
ware.
Red, flashing continuously: Missing connection to main computer,
main computer start-up problem or RobotWare installation problem.
Green, flashing continuously: Missing connections to peripheral
units or RobotWare start-up problem.
Shows the status of Ethernet communication.
Green:
Off:10 Mbps data rate is selected.
On:100 Mbps data rate is selected.
Yellow:
Flashing: The two units are communicating on the Ethernet chan-
nel.
Solid: A LAN link is established.
Off: A LAN link is not established.