ABB OmniCore C30 Product Manual page 227

Hide thumbs Also See for OmniCore C30:
Table of Contents

Advertisement

Refitting the controller covers
Preparations
1
2
Refitting the right side cover
1
2
Product manual - OmniCore C30
3HAC060860-001 Revision: P
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Action
Place the right side cover into the guide
holes and press it into the locking posi-
tion.
Fasten with screws.
© Copyright 2019-2022 ABB. All rights reserved.
5.2.1 Opening the robot controller
Info/illustration
Location of wrist strap button:
xx1800000683
Info/illustration
xx1800000469
Screws: Torx, countersunk screw M4x10 (6
pcs)
xx1800000470
Continues on next page
5 Repair
Continued
227