Use this procedure to configure the robot stopping functions in Visual SafeMove.
Product manual - OmniCore C30
3HAC060860-001 Revision: P
1 In Visual SafeMove, select Stop Configuration.
xx2100000737
2 Select a stop configuration and define the mode (automatic or manual).
ProtectiveStop is the AS/GS input
ExternalEmergencyStop is the ES input
To avoid dead-lock in an emergency stop chain, the
ExternalEmergencyStop input can be decoupled from the ES output.
LocalEmergencyStop is the emergency stop device on the FlexPendant
3 Select the stop category.
For some manipulators, only category 1 stop is available.
4 After the configuration is done, the safety configuration must be written to
the controller and then a restart of the controller is required.
Tip
See also the circuit diagram, Circuit diagram - OmniCore C30, Circuit
diagram - OmniCore C30 for IRB 14050, Circuit diagram - OmniCore C30 for CRB
15000.
© Copyright 2019-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.9 Configuring robot stopping functions
Continues on next page