Refitting the axis computer to the frame
1
Product manual - OmniCore C30
3HAC060860-001 Revision: P
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Insert the incoming mains connector into
the front panel from inner side of the
cabinet.
Secure it with the screws.
Reconnect:
Q0 - A1.X1.
Two ground cables which con-
nects to the left cabinet frame.
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.
© Copyright 2019-2022 ABB. All rights reserved.
5.3.3 Replacing the incoming mains connector
Note/Illustration
Location of wrist strap button:
xx1800000683
Screws: Torx, countersunk screw M4x10 (4
pcs)
xx1800000734
Note/Illustration
5 Repair
Continued
Continues on next page