Refitting the axis computer to the frame
1
2
3
4
5
Concluding procedure
1
2
Product manual - OmniCore C30
3HAC060860-001 Revision: P
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see
Electrical safety on
page
31.
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section
The unit is sensitive to
ESD on page
47.
Reconnect:
K6.X4, K6.X5 - SMB.
Fit the axis computer bracket and secure
the screws.
Reconnect:
K6.X11 - A1.X3
K6.X2 - A2.X9
K6.X1 - K2.X3
Action
Refit the covers.
Perform the function tests to verify that
the safety features work properly, see
Function tests on page
212.
© Copyright 2019-2022 ABB. All rights reserved.
5.3.2.1 Replacing the motor connector
Note/Illustration
Location of wrist strap button:
xx1800000683
Screws: Torx pan head screw M4x8 (4 pcs)
xx1900001201
Note/Illustration
Refitting the controller covers on page
5 Repair
Continued
227.