Enabling and Configuring SNMP Sessions

To enable and configure SNMP sessions, do the following:
Change the mode to Edit Private or Edit Exclusive.
1.
2.
Navigate to admin » snmp. The SNMP Sessions form appears.
Enabling and Configuring SNMP Sessions
MIB
Trap and Description
The main subtree for the RUGGEDCOM software upgrade trap.
trapCfgChangeTrap
The main subtree for the RUGGEDCOM configuration change trap.
trapFanBankTrap
The main subtree for the RUGGEDCOM fan bank trap.
trapHotswapModuleStateChangeTrap
The main subtree for the RUGGEDCOM fan hot-swap module state change trap.
ds1LineStatusChange
DS1-MIB
A ds1LineStatusChange trap is sent when the status of a dsx1Line instance
changes. The value of the trap is the value of one or more of the following
instances:
• dsx1RcvFarEndLOF – Far end Loss of Frames (i.e. yellow alarm or RAI)
• dsx1RcvAIS – Far end sending AIS
• dsx1LossOfFrame – Near end Loss of Frame (i.e. red alarm)
• dsx1LossofSignal – Near end Loss of Signal
• dsx1OtherFailure – Out of Frame
• dsx1NoAlarm