Chapter 5
Setup and Configuration
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
4.
to proceed.
5.
Click Exit Transaction or continue making changes.
Section 5.11.3

Viewing Statistics for SNMP

To view the statistics collected for SNMP, navigate to admin » snmp. The SNMP USM form appears.
Figure 265: SNMP USM Form
This table provides the following information:
Parameter
Unsupported Security Levels
Not In Time Windows
260
Description
Synopsis: The counter32 type represents a non-negative integer that monotonically
increases until it reaches a maximum value of 2^32-1 (4294967295 decimal), when it wraps
around and starts increasing again from zero. Counters have no defined 'initial' value, and
thus, a single value of a counter has (in general) no information content. Discontinuities in
the monotonically increasing value normally occur at re-initialization of the management
system, and at other times as specified in the description of a schema node using this
type. If such other times can occur, for example, the creation of a schema node of type
counter32 at times other than re-initialization, then a corresponding schema node should
be defined, with an appropriate type, to indicate the last discontinuity. The counter32 type
should not be used for configuration schema nodes. A default statement SHOULD NOT be
used in combination with the type counter32. In the value set and its semantics, this type is
equivalent to the Counter32 type of the SMIv2.
The total number of packets received by the SNMP engine which were dropped because
they requested a securityLevel that was unknown to the SNMP engine or otherwise
unavailable.
Synopsis: The counter32 type represents a non-negative integer that monotonically
increases until it reaches a maximum value of 2^32-1 (4294967295 decimal), when it wraps
around and starts increasing again from zero. Counters have no defined 'initial' value, and
thus, a single value of a counter has (in general) no information content. Discontinuities in
the monotonically increasing value normally occur at re-initialization of the management
system, and at other times as specified in the description of a schema node using this
type. If such other times can occur, for example, the creation of a schema node of type
counter32 at times other than re-initialization, then a corresponding schema node should
be defined, with an appropriate type, to indicate the last discontinuity. The counter32 type
should not be used for configuration schema nodes. A default statement SHOULD NOT be
RUGGEDCOM ROX II
User Guide
Viewing Statistics for SNMP