Siemens RUGGEDCOM RX1501 Installation Manual

Hide thumbs Also See for RUGGEDCOM RX1501:

Advertisement

RUGGEDCOM RX1501
Installation Guide
04/2017
RC1054-EN-05
Preface
Introduction
Installing the Device
Modules
Technical Specifications
Dimension Drawings
Certification
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens RUGGEDCOM RX1501

  • Page 1 Preface Introduction Installing the Device RUGGEDCOM RX1501 Modules Technical Specifications Dimension Drawings Installation Guide Certification 04/2017 RC1054-EN-05...
  • Page 2 Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3 RUGGEDCOM RX1501 Installation Guide Industry Sector Tel: +1 905 856 5288 300 Applewood Crescent Fax: +1 905 856 1995 www.siemens.com/ruggedcom Concord, Ontario Canada, L4K 5C7...
  • Page 4 RUGGEDCOM RX1501 Installation Guide...
  • Page 5: Table Of Contents

    RUGGEDCOM RX1501   Installation Guide Table of Contents Table of Contents Preface ......................Alerts ..............................vii Related Documents ..........................viii Accessing Documentation ........................viii Training ............................viii Customer Support ..........................viii Chapter 1 Introduction ..................... 1.1  Feature Highlights ........................1 1.2    Description ........................... 1 Chapter 2 Installing the Device ..................
  • Page 6   RUGGEDCOM RX1501 Table of Contents Installation Guide Chapter 4 Technical Specifications .................. 4.1  Power Supply Specifications ......................31 4.2  Failsafe Relay Specifications ......................32 4.3  Operating Environment ....................... 32 4.4  Mechanical Specifications ......................32 Chapter 5 Dimension Drawings ..................Chapter 6 Certification ....................
  • Page 7: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RUGGEDCOM RX1501. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 8: Related Documents

    Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: • Access Siemens' extensive library of support documentation, including FAQs and manuals • Submit SRs or check on the status of an existing SR •...
  • Page 9: Introduction

    The RUGGEDCOM RX1501 is designed to provide a high level of immunity to electromagnetic interference (EMI) and heavy electrical surges typical of the harsh environments found in many industrial applications. An operating temperature range of -40 to 85 °C (-40 to 185 °F) allows the RUGGEDCOM RX1501 to be placed in almost any location.
  • Page 10 CAUTION! Configuration hazard – risk of data corruption/loss. Do not open the compact flash card port, unless specifically instructed to by a Siemens Customer Support representative. The warranty will be void otherwise. Removing the compact flash card improperly can corrupt configuration data.
  • Page 11: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 12: General Procedure

    Connect power to the device and ground the device to safety Earth. Connect the device to the network. Configure the device. Section 2.2 Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RX1501: Tools/Materials Purpose AC/DC power cord (16 AWG) For connecting power to the device.
  • Page 13: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 14: Mounting The Device

    Mounting the Device The RUGGEDCOM RX1501 is designed for maximum mounting and display flexibility. It can be equipped with connectors that allow it to be installed in a 48 cm (19 in) rack, 35 mm (1.4 in) DIN rail or directly on a panel.
  • Page 15: Mounting The Device On A Din Rail

    Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RX1501 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 16: Mounting The Device To A Panel

    Section 2.4.3 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RX1501 can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 17: Connecting The Failsafe Alarm Relay

    Control of the failsafe relay output is configurable through ROX II. One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the ROX II User Guide for the RUGGEDCOM RX1501. The following shows the proper relay connections.
  • Page 18: Connecting Power

    Section 2.6 Connecting Power The RUGGEDCOM RX1501 supports a single high AC, high DC or low DC power module. Power modules can be equipped with either a screw-type or pluggable terminal block. The screw-type terminal block is installed using Phillips screws and compression plates, allowing either bare wire connections or crimped terminal lugs.
  • Page 19: Connecting High Ac/Dc Power

    RUGGEDCOM RX1501 Chapter 2 Installation Guide Installing the Device • Section 2.6.2, “Connecting Low DC Power” Section 2.6.1 Connecting High AC/DC Power To connect a high AC/DC power supply to the device, do the following: DANGER! Electrocution hazard – risk of death, serious personal injury and/or damage to the device. Make sure the supplied cover is always installed over high voltage screw-type terminal blocks.
  • Page 20 Chapter 2 RUGGEDCOM RX1501 Installing the Device Installation Guide Figure 7: AC Terminal Block Wiring – Screw-Type Terminal Block for HI Power Supplies 1. 5-Position Terminal Block    2. 3-Position Terminal Block    3. Positive/Live (+/L) Terminal    4. Ground Terminal    5. Negative/ Neutral (-/N) Terminal Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block.
  • Page 21: Connecting Low Dc Power

    RUGGEDCOM RX1501 Chapter 2 Installation Guide Installing the Device Section 2.6.2 Connecting Low DC Power To connect a low DC power supply to the device, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Do not connect AC power cables to a 12, 24 or 48 VDC power supply terminal block.
  • Page 22 Chapter 2 RUGGEDCOM RX1501 Installing the Device Installation Guide Figure 10: DC Terminal Block Wiring – Screw-Type Terminal Block for 12, 24 and 48 Power Supplies 1. 5-Position Terminal Block    2. 3-Position Terminal Block    3. Positive (+) Terminal    4. Negative (-) Terminal    5. Ground Terminal Connect the positive wire from the power source to the positive (+) terminal on the terminal block.
  • Page 23: Connecting To The Device

    For information about how to connect to the device via the management port, refer to either the RUGGEDCOM ROX II Web Interface User Guide or the RUGGEDCOM ROX II CLI User Guide for the RUGGEDCOM RX1501. The management port is a 10/100Base-TX copper Ethernet port with an RJ-45 connector. The following is the pin-...
  • Page 24: Configuring The Device

    Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the ROX II console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM RX1501 is https://192.168.0.2 For more information about available ports, refer to Chapter 3, Modules...
  • Page 25: Modules

    Modules Modules The RUGGEDCOM RX1501 features slots for up to four field-replaceable line modules, which can be used to expand and customize the capabilities of the device to suit specific applications. A variety of modules are available, each featuring a specific type of communication port: copper Ethernet, fiber optic Ethernet, SFP, WAN, cellular modem and DDS.
  • Page 26: Available Modules

    Section 3.3, “Installing/Removing Power Modules” Section 3.1 Available Modules The following is a list of all power and line modules available for use in the RUGGEDCOM RX1501. For more information about individual modules, refer to the RUGGEDCOM RX1500 Series Modules Catalog [https:// support.industry.siemens.com/cs/ca/en/view/109747072].
  • Page 27 RUGGEDCOM RX1501 Chapter 3 Installation Guide Modules RUGGEDCOM RX1500PN PS 48 Specifications Article Numbers Input Range: 36 to 72 VDC 6GK60150AL120AA0 (Standard) Terminal Type: Screw 6GK60150AL120AA1 (Conformal Coated) RUGGEDCOM RX1500PN PS 48P Specifications Article Numbers Input Range: 36 to 72 VDC...
  • Page 28 Chapter 3 RUGGEDCOM RX1501 Modules Installation Guide RUGGEDCOM RX1500PN M12 CG03B Specifications Article Numbers Ports: 2 6GK60150AL200PE0 (Standard) Speed: 10/100/1000Base-TX 6GK60150AL200PE1 (Conformal Coated) Port Type: M12 (8-Pin, A-Coded, Controlled Bypass) Distance: 100 m (328 ft) RUGGEDCOM RX1500PN M12 X CG04...
  • Page 29 RUGGEDCOM RX1501 Chapter 3 Installation Guide Modules Fiber Optic Ethernet Modules RUGGEDCOM RX1500PN LM 4FX11 Specifications Article Numbers Mode: MM 6GK60150AL200BC0 (Standard) Speed: 100Base-FX 6GK60150AL200BC1 (Conformal Coated) Wavelength: 1300 nm Ports: 4 Port Type: LC Distance: 2 km (1.2 mi)
  • Page 30 Chapter 3 RUGGEDCOM RX1501 Modules Installation Guide RUGGEDCOM RX1500PN LM S01 Specifications Article Numbers Speed: RS232/RS422/RS485 6GK60150AL200KB0 (Standard) Ports: 6 6GK60150AL200KB1 (Conformal Coated) Port Type: RJ45 RUGGEDCOM RX1500PN LM TC1 Specifications Article Numbers Interface: T1/E1 6GK60150AL200MB0 (Standard) Ports: 1 6GK60150AL200MB1...
  • Page 31 RUGGEDCOM RX1501 Chapter 3 Installation Guide Modules Antennas: 1 x EVDO Rev A, 1 x Receive Diversity (Secondary) SIM: Dual Mini-SIM (2FF) RUGGEDCOM RX1500PN LM W22 Specifications Article Numbers Services: EVDO Rev A 6GK60150AL200WE0 (Standard) Region: North America (Verizon) 6GK60150AL200WE0 (Conformal Coated) Port Type: 50 Ω...
  • Page 32 Chapter 3 RUGGEDCOM RX1501 Modules Installation Guide Antennas: 1 x LTE Main, 1 x LTE MIMO, 1 x GPS SIM: Dual Mini-SIM (2FF) RUGGEDCOM APE Modules CAUTION! Electrical hazard – risk of power failure. Do not install more than two RUGGEDCOM APE modules.
  • Page 33: Installing/Removing Line Modules

    RUGGEDCOM RX1501 Chapter 3 Installation Guide Modules RUGGEDCOM RX1500PN LM APE1404W7 Specifications Article Numbers Operating System: Windows® 6GK60150AL200GE0 (Standard) Embedded Standard 7 6GK60150AL200GE1 (Conformal Processor: Intel Atom E660T 1.3 Coated) GHz, 512 KB L2 Cache RAM: 2 GB DDR2, 800 MHz, 32-...
  • Page 34 Chapter 3 RUGGEDCOM RX1501 Modules Installation Guide CAUTION! Contamination hazard – risk of equipment damage. Prevent the ingress of water, dirts and other debris that may lead to premature equipment failure. Always make sure slots are not left empty and open ports are protected with plugs or covers.
  • Page 35: Installing/Removing Power Modules

    [Optional] If necessary, install the device in the rack. Connect power to the device. Section 3.3 Installing/Removing Power Modules The RUGGEDCOM RX1501 supports a single power module. Figure 17:  Power Module 1. Power Module CAUTION! Contamination hazard – risk of equipment damage. Prevent the ingress of water, dirts and other debris that may lead to premature equipment failure.
  • Page 36 Chapter 3 RUGGEDCOM RX1501 Modules Installation Guide Figure 18: Removing a Power Supply 1. Chassis    2. Power Supply    3. Screws DANGER! Electrocution hazard – risk of serious personal injury or death. Make sure power to the module is turned off before servicing the power supply terminal.
  • Page 37 RUGGEDCOM RX1501 Chapter 3 Installation Guide Modules Figure 19: Installing a Power Module 1. Chassis    2. Power Module    3. Screws Hand-tighten the screws to secure the power module to the chassis. Turn on power to the module and confirm the module is receiving and supplying power. This is indicated by the LEDs on the module.
  • Page 38 Chapter 3 RUGGEDCOM RX1501 Modules Installation Guide Installing/Removing Power Modules...
  • Page 39: Technical Specifications

    RUGGEDCOM RX1501 Chapter 4 Installation Guide Technical Specifications Technical Specifications This section provides important technical specifications related to the device. CONTENTS • Section 4.1, “Power Supply Specifications” • Section 4.2, “Failsafe Relay Specifications” • Section 4.3, “Operating Environment” • Section 4.4, “Mechanical Specifications” Section 4.1...
  • Page 40: Failsafe Relay Specifications

    Temperature limits for select line modules may differ from that which can be withstood by the RUGGEDCOM RX1501. Make sure the selected modules are rated for the expected environmental conditions before deployment. For more information, refer to the RUGGEDCOM RX1501 Series Modules Catalog.
  • Page 41: Dimension Drawings

    RUGGEDCOM RX1501 Chapter 5 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 440.9 Figure 20: Overall Dimensions...
  • Page 42 Chapter 5 RUGGEDCOM RX1501 Dimension Drawings Installation Guide 11.7 463.8 21.1 Figure 21: Rack Mount Dimensions 479.0 11.7 21.1 489.2 Figure 22: Panel and Din Rail Mount Dimensions...
  • Page 43 RUGGEDCOM RX1501 Chapter 5 Installation Guide Dimension Drawings 162.5 151.4 19.7 Figure 23: Line Module Dimensions 162.5 151.8 40.6 Figure 24: Power Module Dimensions...
  • Page 44 Chapter 5 RUGGEDCOM RX1501 Dimension Drawings Installation Guide...
  • Page 45: Certification

    Installation Guide Certification Certification The RUGGEDCOM RX1501 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. NOTE Certifications related to individual modules are detailed in the RUGGEDCOM Modules Catalog for the device available online.
  • Page 46: Tüv Süd

    Information Technology Equipment – Safety – Part 1: General Requirements) Section 6.1.3 European Union (EU) This device is declared by Siemens Canada Ltd to comply with essential requirements and other relevant provisions of the following EU directives: • Directive 2014/30/EU Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to electromagnetic compatibility (recast) Text with EEA relevance •...
  • Page 47: Fcc

    The device is marked with a CE marking and notified body number, and can be used throughout the European community. 0680 A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd. For contact information, refer to “Contacting Siemens ” Section 6.1.4 This device has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 48: Rohs

    Installation Guide Section 6.1.7 RoHS This device is declared by Siemens Canada Ltd to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: • China RoHS 2...
  • Page 49 EMC Immunity Type Tests for IEEE 1613 NOTE The RUGGEDCOM RX1501 meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires error-free and interrupted communications.
  • Page 50 Chapter 6 RUGGEDCOM RX1501 Certification Installation Guide Description Test Levels HV Impulse Signal ports 5 kV (Failsafe Relay Output) DC Power Ports 5 kV AC Power Ports Dielectric Strength Signal ports 2 kV DC Power Ports 1.5 kV AC Power Ports...