Viewing The Slot Sensor Status; Viewing The Power Controller Status - Siemens RX1500 User Manual

Ruggedcom rox ii series
Hide thumbs Also See for RX1500:
Table of Contents

Advertisement

Chapter 3
Device Management
Parameter
Status
Uptime
Boot Date
Boot Time
Section 3.2.6

Viewing the Slot Sensor Status

To view information about the slot sensors, navigate to chassis » sensors. The Slot Sensors table appears..
Figure 24: Slot Sensors Table
This table provides the following information:
Parameter
slot
Detected Module
Temperature (degrees C)
Power Supply (mA)
Power Supply (mV)
Section 3.2.7

Viewing the Power Controller Status

To view the status of the power controller, navigate to chassis » power-controller. The Power Status table
appears.
36
Description
The runtime status of the installed module.
The total time elapsed since the start-up of the installed module.
The date on which the installed module was started up.
The time at which the installed module was started up.
Description
Synopsis: pm1, pm2, main, sm, lm1, lm2, lm3, lm4, lm5, lm6, cm, em, trnk
The slot name, as marked on the silkscreen across the top of the chassis.
The installed module's type specifier.
The temperature, in degrees C, of the installed module. If multiple temperature sensors are
present on the board, the maximum reading is reported.
The power supply current, in mA, being drawn by the installed module.
The power supply voltage, in mV, seen by the installed module.
RUGGEDCOM ROX II
User Guide
Viewing the Slot Sensor Status