Chapter 3
Device Management
Figure 30: Trigger Action Form
1. Perform Button
On the Restore Factory Defaults form, configure the following parameter(s) as required:
2.
Parameter
delete-logs
default-both-partitions
delete-saved-configurations
shutdown
3.
On the Trigger Action form, click Perform.
Section 3.7
Decommissioning the Device
Before taking the device out of service, either permanently or for maintenance by a third-party, make sure the
device has been fully decommissioned. This includes removing any sensitive, proprietary information.
To decommission the device, do the following:
1.
Obtain a copy of the ROX II firmware currently installed on the device. For more information, contact
Siemens Customer Support.
2.
Log in to maintenance mode. For more information, refer to the ROX II v2.6 CLI User Guide.
3.
Delete the current boot password/passphrase by typing:
rox-delete-bootpwd --force
Type exit and press Enter.
4.
5.
Log in to ROX II. For more information, refer to
6.
Flash the ROX II firmware obtained in
information, refer to
40
Description
Default: false
Delete system logs as well as restoring default settings.
Default: false
Perform the operation on both partitions.
Default: false
Delete saved configuration files (works with default-both-partitions option).
Default: false
Shutdown rather than reboot after restoring factory defaults.
Step 1
Section 3.11.5.2, "Downgrading Using
Section 2.3, "Logging
In".
to the inactive partition and reboot the device. For more
ROXflash".