Restarting The Serial Server; Resetting A Serial Port - Siemens RX1500 User Manual

Ruggedcom rox ii series
Hide thumbs Also See for RX1500:
Table of Contents

Advertisement

Chapter 3
Device Management
Parameter
parity
stop-bits
flow-control
port-type
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
4.
to proceed.
Click Exit Transaction or continue making changes.
5.
Section 3.20.7

Restarting the Serial Server

To restart the serial server, do the following:
Navigate to interfaces » serial and click restart-serserver in the menu. The Trigger Action form appears.
1.
Figure 120: Trigger Action Form
1. Perform Button
2.
Click Perform.
Section 3.20.8

Resetting a Serial Port

To reset a serial port, do the following:
118
Description
The number of data bits.
Synopsis: none, even, odd
Default: none
The parity of the serial port.
Default: 1
The number of stop bits of the serial port.
Synopsis: none, xonxoff
Default: none
The flow control of the serial port.
Synopsis: rs232, rs422, rs485
Default: rs232
The type of serial port.
RUGGEDCOM ROX II
User Guide
1
Restarting the Serial Server