Chapter 5
Setup and Configuration
Parameter
size
low-value
high-value
11. On the Remote Cookie form, configure the following parameter(s) as required:
Parameter
size
low-value
high-value
12. Navigate to tunnel » l2tpv3 » static » tunnel » {tunnel name} » session » {session name} » vlan and
select Add vlan. The Key Settings form appears.
Figure 758: Key Settings Form
1. Vid Field
2. Add Button
On the Key Settings form, configure the following parameter(s) as required:
Parameter
vid
For more information about VLANs, refer to
13. Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
14. Click Exit Transaction or continue making changes.
646
Description
Synopsis: 4, 8
Cookie size in byte.
Lower value of cookie. This value must match with low-value of other endpoint's remote
cookie
Higher value of cookie if the cookie size is 8. This value must match with high-value of
other endpoint's remote cookie
Description
Synopsis: 4, 8
Cookie size in byte
Lower value of cookie. This value must match with low-value of other endpoint's local
cookie
Higher value of cookie if its size is 8. This value must match with high-value of other
endpoint's local cookie
1
Description
VLAN ID for this routable logical interface
Section 5.35, "Managing
2
VLANs".
Configuring L2TPv3 Tunnels
RUGGEDCOM ROX II