RUGGEDCOM ROX II
User Guide
Figure 733: ESP Encryption Algorithm Form
1. Mod Group List
3.
Configure the following parameter(s) as required:
Parameter
Modpgroup
4.
If required, add additional cipher algorithms. For more information on how to add algorithms, refer to
Section 5.28.8.3, "Adding ESP Algorithms"
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
5.
to proceed.
Click Exit Transaction or continue making changes.
6.
Section 5.28.8.2

Viewing a List of ESP Algorithms

To view a list of algorithms for the Encapsulate Security Payload (ESP) protocol, navigate to tunnel » ipsec »
connection » {connection} » esp » algorithm, where {connection} is the name of the connection. If algorithms
have been configured, the Algorithm table appears.
Figure 734: Algorithm Table
If no algorithms have been configured, add algorithms as needed. For more information, refer to
"Adding ESP
Algorithms".
Viewing a List of ESP Algorithms
1
Description
Synopsis: modp1024, modp1536, modp2048, modp3072, modp4096, modp6144,
modp8192, any
Default: any
The Modular Exponential (MODP) group. The default value is 'modp1024' or 'modp1536'
unless overwritten by the default connection setting.