Chapter 5
Setup and Configuration
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
7.
to proceed.
8.
Click Exit Transaction or continue making changes.
Section 5.27.4.3

Deleting a Link Failover Backup Interface

To delete a link failover backup interface, do the following:
1.
Change the mode to Edit Private or Edit Exclusive.
2.
Navigate to services » link-failover » {interface} » backup, where {interface} is the name of the interface.
The Backup Information table appears.
1
Figure 710: Backup Information Table
1. Add Button
2. Edit Button
3.
Click Delete next to the chosen backup interface.
4.
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
5.
Click Exit Transaction or continue making changes.
Section 5.27.5

Managing Link Failover Ping Targets

A link failover ping target is an IP address that link failover pings to determine if the main link is down. The
address can be a dedicated host or a dummy address on a router. Up to three link failover ping targets can be
added to each link failover configuration.
The following sections describe how to configure and manage ping targets for link failover protection:
Section 5.27.5.1, "Viewing a List of Link Failover Ping Targets"
Section 5.27.5.2, "Adding a Link Failover Ping Target"
Section 5.27.5.3, "Deleting a Link Failover Ping target"
608
3. Delete Button
2
3
Deleting a Link Failover Backup Interface
RUGGEDCOM ROX II
User Guide