RUGGEDCOM ROX II
User Guide
Parameter
Transmission Delay (sec)
Notification Interval (sec)
4.
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
5.
Click Exit Transaction or continue making changes.
Section 5.36.2

Viewing Global Statistics and Advertised System Information

To view global statistics for LLDP and the system information that is advertised to neighbors, navigate to switch »
net-discovery » lldp. The LLDP Global Statistics and LLDP Local System forms appear.
Figure 866: LLDP Global Statistics Form
1. Inserts
2. Deletes
Viewing Global Statistics and Advertised System
Information
Description
Default: 2
The delay in seconds between successive LLDP frame transmissions initiated by the
value or status changed. The recommended value is set by the following formula: 1 is
less than or equal to txDelay less than or equal to (0.25 * Tx Interval)
Default: 5
Controls transmission of LLDP traps. The agent must not generate more than one trap
in an indicated period.
1
2
3
4
5
3. Drops
4. Ageouts