Viewing The Status Of Reference Clocks - Siemens RX1500 User Manual

Ruggedcom rox ii series
Hide thumbs Also See for RX1500:
Table of Contents

Advertisement

Chapter 5
Setup and Configuration
Parameter
NTP Service Status
A character before an address is referred to as a tally code. Tally codes indicate the fate of the peer in the clock
selection process. The following describes the meaning of each tally code:
Tally Code
blank
x
.
-
+
#
*
o
Section 5.12.9

Viewing the Status of Reference Clocks

To view the status of reference clocks, navigate to services » time » ntp » status » reference-clocks. The
Reference Clocks table appears.
Figure 297: Reference Clocks Table
This table provides the following information:
Parameter
Remote IP
State
RefId
Stratum
286
Description
Use this action to get the current NTP running status.
Description
A blank tally code indicates the peer has been discarded either because it is unreachable, it is synchronized to
the same server (synch loop) or the synchronization distance is too far.
This tally code indicates the peer has been discarded because its clock is not correct. This is referred to as a
falseticker.
This tally code indicates the peer has been discarded because its synchronization distance is too poor to be
considered a candidate.
This tally code indicates the peer has been discarded because its offset is too a significant compared to the
other peers. This is referred to as an outlier.
This tally code indicates the peer is considered a candidate.
This tally code indicates the peer is considered a candidate, but it is not among the top six sorted by
synchronization distance. If the association is short-lived, it may be demobilized to conserve resources.
This tally code indicates the peer is the system peer.
This tally code indicates the peer is the system peer, but the synchronization distance is derived from a Pulse-
Per-Second (PPS) signal.
Description
The IP address of the reference clock.
The state of the clock.
The identification of the reference clock.
The stratum number of the reference clock.
RUGGEDCOM ROX II
Viewing the Status of Reference Clocks