Chapter 5
Setup and Configuration
Section 5.16.3, "Managing Ingress Source Ports"
Section 5.16.1

Configuring Port Mirroring

To configure port mirroring, do the following:
Change the mode to Edit Private or Edit Exclusive.
1.
2.
Navigate to switch » port-mirroring. The Port Mirror form appears.
Figure 396: Port Mirror Form
1. Target Slot List
3.
Configure the following parameter(s) as required:
Parameter
Target Slot
Target Port
Admin State
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
4.
to proceed.
Click Exit Transaction or continue making changes.
5.
Section 5.16.2

Managing Egress Source Ports

The following sections describe how to configure and manage egress source ports for port mirroring:
Section 5.16.2.1, "Viewing a List of Egress Source Ports"
Section 5.16.2.2, "Adding an Egress Source Port"
Section 5.16.2.3, "Deleting an Egress Source Port"
362
1
2
2. Admin State Check Box
Description
Synopsis: sm, lm1, lm2, lm3, lm4, lm5, lm6
The slot where a monitoring device should be connected.
The port where a monitoring device should be connected.
Enabling port mirroring causes all frames received and/or transmitted by the source port
to be transmitted out of the target port.