RUGGEDCOM ROX II
User Guide
Parameter
main-down-timeout
main-up-timeout
6.
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
7.
Click Exit Transaction or continue making changes.
Section 5.27.3.3

Deleting a Link Failover Parameter

To delete a link failover parameter, do the following:
1.
Change the mode to Edit Private or Edit Exclusive.
2.
Navigate to services » link-failover. The Link Failover Information table appears.
1
Figure 706: Link Failover Information Table
1. Add Button
3.
Click Delete next to the chosen parameter.
4.
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
5.
Click Exit Transaction or continue making changes.
Section 5.27.4

Managing Link Failover Backup Interfaces

A backup interface is the interface to which link failover switches when the main interface is determined to be
down. You can add up to three backup interfaces to each link failover configuration.
The following sections describe how to configure and manage backup interfaces for link failover protection:
Section 5.27.4.1, "Viewing a List of Link Failover Backup Interfaces"
Section 5.27.4.2, "Adding a Link Failover Backup Interface"
Section 5.27.4.3, "Deleting a Link Failover Backup Interface"
Deleting a Link Failover Parameter
Description
Default: 60
The delay time, in seconds, that the main trunk is down before starting the backup trunk.
Default: 60
The delay time, in seconds, to confirm that the main trunk is up (returned to service)
before stopping the backup trunk.