RUGGEDCOM ROX II
User Guide
2.
Depending on the dynamic routing protocol being configured, navigate to routing » dynamic » rip » filter »
{name} » entry, where {name} is the name of the prefix list.
3.
Click <Add entry>. The Key Settings form appears.
Figure 510: Key Settings Form
1. Sequence Number Box
4.
Configure the following parameter(s) as required:
Parameter
Sequence Number
5.
Click Add to create the new entry. The Prefix List Entry form appears.
Figure 511: Prefix List Entry Form
1. ActionList
2. Network Box
6.
Configure the following parameter(s) as required:
Parameter
Action
Adding a Prefix Entry
1
2. Add Button
Description
Sequence number of the entry.
1
2
3
4
3. Maximum Prefix to Mask for Subnet
Description
Synopsis: deny, permit
4. Minimum Prefix to Mask for Subnet
Chapter 5
Setup and Configuration
2
455