Siemens RX1500 User Manual page 531

Ruggedcom rox ii series
Hide thumbs Also See for RX1500:
Table of Contents

Advertisement

RUGGEDCOM ROX II
User Guide
Figure 572: Send Life Time Form
1. Time to Start Box
6.
On the Key Configuration form, configure the following parameter(s) as required:
Parameter
Key
7.
On the Accept Life Time form, configure the following parameter(s) as required:
Parameter
Time to Start
Expire Time
Adding a Key
1
2
2. Expire Time Box
Description
Sets the key string.
Description
Synopsis: The date-and-time type is a profile of the ISO 8601 standard for
representation of dates and times using the Gregorian calendar. The profile is defined
by the date-time production in Section 5.6 of RFC 3339. The date-and-time type is
compatible with the dateTime XML schema type with the following notable exceptions:
(a) The date-and-time type does not allow negative years. (b) The date-and-time time-
offset -00:00 indicates an unknown time zone (see RFC 3339) while -00:00 and +00:00
and Z all represent the same time zone in dateTime. (c) The canonical format (see
below) of data-and-time values differs from the canonical format used by the dateTime
XML schema type, which requires all times to be in UTC using the time-offset 'Z'.
This type is not equivalent to the DateAndTime textual convention of the SMIv2 since
RFC 3339 uses a different separator between full-date and full-time and provides
higher resolution of time-secfrac. The canonical format for date-and-time values with a
known time zone uses a numeric time zone offset that is calculated using the device's
configured known offset to UTC time. A change of the device's offset to UTC time
will cause date-and-time values to change accordingly. Such changes might happen
periodically in case a server follows automatically daylight saving time (DST) time zone
offset changes. The canonical format for date-and-time values with an unknown time
zone (usually referring to the notion of local time) uses the time-offset -00:00.
The beginning time in which the key is considered valid.
Prerequisite: The start time cannot be configured unless the expire time is configured.
Synopsis: The date-and-time type is a profile of the ISO 8601 standard for
representation of dates and times using the Gregorian calendar. The profile is defined
by the date-time production in Section 5.6 of RFC 3339. The date-and-time type is
compatible with the dateTime XML schema type with the following notable exceptions:
(a) The date-and-time type does not allow negative years. (b) The date-and-time time-
offset -00:00 indicates an unknown time zone (see RFC 3339) while -00:00 and +00:00
and Z all represent the same time zone in dateTime. (c) The canonical format (see
below) of data-and-time values differs from the canonical format used by the dateTime
XML schema type, which requires all times to be in UTC using the time-offset 'Z'.
This type is not equivalent to the DateAndTime textual convention of the SMIv2 since
RFC 3339 uses a different separator between full-date and full-time and provides
higher resolution of time-secfrac. The canonical format for date-and-time values with a
known time zone uses a numeric time zone offset that is calculated using the device's
configured known offset to UTC time. A change of the device's offset to UTC time
Chapter 5