Chapter 3
Device Management
Section 3.23.6

Configuring a Cellular Modem Interface

To configure a cellular modem interface, do the following:
NOTE
Cellular modems with support for EDVO network technology is backward compatible with CDMA 2G
and CDMA 1x RTT networks.
Cellular modems with support for HSPA+ network technology is backward compatible with GSM,
GPRS, EDGE, UMTS, HSDPA/HSUPA networks.
1.
Change the mode to Edit Private or Edit Exclusive.
2.
Navigate to interface » wan » {interface}, where {interface} is the cellular modem interface. The Routable
Cellular Modem Interfaces form appears.
Figure 150: Routable Cellular Modem Interfaces Form
1. Enabled Check Box
3.
Configure the following parameter(s) as required:
Parameter
enabled
link-alarms
alias
4.
Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
Click Exit Transaction or continue making changes.
5.
146
1
2
3
2. Link Alarms Check Box
3. Alias Box
Description
Default: false
Provides the option to enable or disable this interface. When unchecked(i.e disabled),
the interface will prevent all frames from being sent and received on that interface.
Default: true
Disabling link-alarms will prevent alarms and LinkUp and LinkDown SNMP traps from
being sent for that interface. Link alarms may also be controlled for the whole system
under admin / alarm-cfg.
The SNMP alias name of the interface
RUGGEDCOM ROX II
Configuring a Cellular Modem Interface