Message
The following VDs have missing disks: X Y.. If
you proceed (or load the configuration utility),
these VDs will be marked OFFLINE and will be
inaccessible. Please check your cables and
ensure all disks are present.
A discovery error has occurred, please power
cycle the system and all the enclosures attached
to this system.
The following VDs are missing: X Y ... If you
proceed (or load the configuration utility), these
VDs will be removed from your configuration. If
you wish to use them at a later time, they will
have to be imported. If you believe these VDs
should be present, please power off your system
and check your cables to ensure all disks are
present.
All of the disks from your previous configuration
are gone. If this is an unexpected message, then
please power off your system and check your
cables to ensure all disks are present.
Press any key to continue, or 'C' to load the
configuration utility.
Press <Ctrl> <H> for WebBIOS.
Your battery is bad or missing, and you have VDs
configured for write-back mode. Because the
battery is not usable, these VDs will actually run
in write-through mode until the battery is
replaced.
Multibit ECC errors were detected on the
controller. DIMM on the controller needs
replacement. If you continue, data corruption can
occur.
Press 'X' to continue or else power off the system
and replace the DIMM module and reboot. If you
have replaced the DIMM, please press 'X' to
continue.
Single-bit ECC errors were detected during the
previous boot of the RAID controller. The DIMM
on the controller needs replacement. Please
contact technical support to resolve this issue.
Press 'X' to continue or else power off the system
and replace the DIMM module and reboot. If you
have replaced the DIMM, press 'X' to continue.
Description
Since some hard disks have been removed, the
disk array is set in OFF LINE.
When this message is displayed even if the device
is installed properly, contact your reseller or call
maintenance personnel.
A disk array controller or hard disk has not been
recognized correctly. When this message is
displayed, contact your reseller or call
maintenance personnel.
Some disk array configurations are removed.
When this message is displayed even if the device
is installed properly, contact your reseller or call
maintenance personnel.
All hard disks with disk array configuration
information have been removed.
When this message is displayed even if the device
is installed properly, contact your reseller or call
maintenance personnel.
Press the C key while this message is displayed,
MegaRAID WebBIOS will start.
When this message is displayed, press the Ctrl
and H keys at the same time to start MegaRAID
WebBIOS.
Write cache is not enabled because MegaRAID
Storage Manager has set the write policy (write
cache setting) to Write Back. Do not change the
write cache from the MegaRAID Storage Manager
any more.
Change the write policy setting from MegaRAID
WebBIOS referring to
"Changing the write policy
for disk
arrays".
An error has occurred in the cache memory of the
disk array controller.
When this message is displayed, contact your
reseller or call maintenance personnel.
322