Mitsubishi Electric GOT2000 Series Connection Manual page 88

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

Item
[Motion
controller(S
SCNETIII/
H)],
[Simple
motion(SSC
NETIII/H)],
[Master
module(CCI
EF)]
Device
[Network
No.n]
Information
Displays the device type and its setting range selected in [Device].
Set the station number of the controller to be monitored.
CPU No.
Host
Network
Other
Reading the device comment data created by GX Developer and confirming the device comment/device name are available during device
Swich to the
setting.
device comment
For details on the procedure to refer to the device comment, refer to the following.
dialog
GT Designer3 (GOT2000) Screen Design Manual
2 - 4
This item can be set only when The following devices are selected.
• Servo amplifier request (SP)
• Operation mode selection (OM)
• Instruction demand (for test operation) (TMB)
• One-touch tuning (OTI)
• Basic parameter (PA)
• Gain filter parameter (PB)
• Extension setting parameter (PC)
• I/O setting parameter (PD)
• Positioning control parameter (PT)
• Linear servo motor/DD motor setting parameter (PL)
• Network setting parameter (PN)
• Status display (ST)
• Extension setting 2 parameter (PE)
• Extension setting 3 parameter (PF)
• Alarm (current alarm, extended for J4) (ALM)
• Alarm (alarm history, extended for J4) (ALM)
• Point table (position) (POS)
• Point table (speed) (SPD)
• Point table (acceleration time constant) (ACT)
• Point table (deceleration time constant) (DCT)
• Point table (dwell) (DWL)
• Point table (auxiliary function) (AUX)
• Machine diagnosis data (MD)
• One-touch tuning data (OTS)
• External input (DI)
• External output (DO)
• Lifetime diagnosis (ALD)
• Input signal for test operation (for test operation) (TMI)
• Forced output of signal pin (for test operation) (TMO)
• Set data (for test operation) (TMD)
This item can be set only when the [Simple motion(SSCNETIII/H)] is selected.
[Unit No.]
Set the slot position of the connected simple motion module.
This item can be set only when the [Motion controller] or [Simple motion] is selected.
[Axis No.]
Set the axis number of the servo amplifier to be monitored.
This item can be set only when the following devices are selected.
The value set in device name n is input.
• Link input (link direct)(JnX)
• Link output (link direct)(JnY)
• Link relay (link direct)(JnB)
• Link special relay (link direct)(JnSB)
• Link register (link direct)(JnW)
• Link special register (link direct)(JnSW)
Example of device display
1-1/1 J1-X0000
If 1 is input into the device name "JnX" with [Network No. n], 1 will appear at the n.
Set the CPU No. of the controller.
(1)Setting of the CPU No.
Select this item for monitoring the host controller.
Select this for monitoring other controllers.
After selecting the item, set the station number and network number of the controller to be monitored.
NW No.: Set the network No.
Station No.: Set the station No.
Description