Communication Detail Settings - Mitsubishi Electric GOT2000 Series Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000 Series:
Table of Contents

Advertisement

2.4.2

Communication detail settings

Make the settings according to the usage environment.
■1. HITACHI HIDIC H
Item
Transmission Speed
Data Bit
Stop Bit
Parity
Retry
Timeout Time
Delay Time
*1
Station No. Selection
*1
2 - 8
2.4 GOT Side Settings
Set this item when change the transmission
speed used for communication with the
connected equipment.
(Default: 19200bps)
Set this item when change the data length used
for communication with the connected
equipment.
(Default: 7bit)
Specify the stop bit length for communications.
(Default: 1bit)
Specify whether or not to perform a parity check,
and how it is performed during communication.
(Default: Even)
Set the number of retries to be performed when
a communication error occurs.
(Default: 0time)
Set the time period for a communication to time
out.
(Default: 3sec)
Set this item to adjust the transmission timing of
the communication request from the GOT.
(Default: 0ms)
Specify whether to use the station No. during
communication.
If [Yes] is selected, the station No. is fixed to "0."
(Default: Yes)
By PLC port that is connected to the GOT, different [Station No. Selection] of the set as follows.
When a PLC port is RS422 port: [Yes]
When a PLC port is S232C port: [No]
Description
Range
4800bps,
9600bps,
19200bps,
38400bps
7bit (fixed)
1bit (fixed)
Even (fixed)
0 to 5times
1 to 30sec
0 to 300 (ms)
Yes or No