2.5

MELSEC-QnA, MELDAS C6 *

The device ranges that can be set when selecting [MELSEC-QnA/, MELDAS C6*] as the controller type are as follows.
Input (X)
Output (Y)
Internal relay (M)
Latch relay (L)
Annunciator (F)
Link relay (B)
*8
Timer
Bit device
*8
Counter
Special relay (SM)
Retentive timer
Step relay (S)
Link special relay (SB)
The bit specification of the word device
(except Timer, Counter, Retentive timer, Index register)
Data register (D)
Special data register (SD)
Link register (W)
Timer (current value) (TN)
Counter (current value) (CN)
Retentive timer
(current value) (SN)
Link special register (SW)
File register (R)
Word device
Extension file register (ER)
Extension file register (ZR)
Index register (Z)
Buffer memory (Intelligent function module) (G)
Remote register (Ww)
Remote register (Wr)
The word specification of the bit device
(except Timer, Counter, Retentive timer)
*1
*2
*3
*4
*5
*6
*7
*8
*9
*10
2 - 58
2.5 MELSEC-QnA, MELDAS C6 *
*6*7*10
Device name
*8
Contact (TT)
Coil (TC)
Contact (CT)
Coil (CC)
Contact (SS)
*8
Coil (SC)
*8
*8
*8
*8
*1*2
Block
*1*9*11
Device
*1*3*9*11
*4*9
*4*9
*5
Do not set a file register by GT Designer3 when executing multiple programs with the file of the file register set at [Use the same
file name as the program] by the PLC parameter of GX Developer.(Except MELSEC-QnA)
Otherwise, read/write at GOT will be erroneous.
Available for file register of block No. switched with the RSET instruction.
Available for file register of block No. of file name switched with the QDRSET instruction.
This is not supported by GT21.
The device No. must be set in multiples of 16.
When monitoring MELDAS C6/64, if a word device outside the range is set, the value becomes indefinite.
When a bit device outside the range is set, the object may not be displayed or the set function may fail to operate.
Check the set device using the device list of GT Designer3.
Devices used by the MELDAS C6/64 system cannot be used.
Do not use local devices set in the MELSEC-Q system.
Otherwise, normal monitoring is not performed.
This cannot be monitored when in GOT multi-drop connection.
Only reading is possible from QS001CPU.
X0 to X3FFF
Y0 to Y3FFF
M0 to M32767
L0 to L32767
F0 to F32767
B0 to B7FFF
TT0 to TT32767
TC0 to TC32767
CT0 to CT32767
CC0 to CC32767
SM0 to SM2047
SS0 to SS32767
SC0 to SC32767
S0 to S32767
SB0 to SB7FFF
Setting range of each word device
D0 to D32767
SD0 to SD2047
W0 to W7FFF
TN0 to TN32767
CN0 to CN32767
SN0 to SN32767
SW0 to SW7FFF
R0 to R32767
0 to 255
R0 to R32767
ZR0 to ZR1042431
Z0 to Z15
*9*11
G0 to G65535
Ww0 to Ww1FFF
Wr0 to Wr1FFF
Setting range of each bit devices
Setting range
Device No.
representation
Hexadecimal
Decimal
Hexadecimal
Decimal
Hexadecimal
Decimal
Hexadecimal
Decimal
Hexadecimal
Decimal
Hexadecimal