23.4.15 Connecting to PERIPHERAL I/
F (Built-in Ethernet port Motion
Controller CPU)
This section describes the settings of the GOT and Built-in
Ethernet port motion controller CPU in the following case of
system configuration.
POINT
POINT
POINT
(1) GOT type setting
For details, refer to the following.
GOT1000 Series Connection Manual for GT
Works3
1.1.1 Setting connected equipment (Channel
setting)
(2) Setting [Controller Type]
(2) CPU No. specification of Q170MCPU
Set whether to monitor the PLC CPU area or the
Motion CPU area of Q170MCPU, in the CPU No.
specification. For details, refer to the following.
23.5 Precautions
(3) PLC type of GX Works2/GX Developer
When creating a program, set the following PLC
type:
• For Q173D(S)CPU/Q172D(S)CPU
QnUD(E)(H)CPU
• For Q170MCPU
Q03UDCPU
(4) Built-in Ethernet port CPU
For details of Built-in Ethernet port CPU, refer to
the following manual.
User's Manual of Q173D(S)CPU/
Q172D(S)CPU, and Q170MCPU
System configuration
Leave the Built-in Ethernet port Motion Controller CPU
settings as default in the following system
configuration. Set [Ethernet] for [Controller Setting] on
GT Designer3, and then connect Built-in Ethernet port
QCPU to the GOT.
[Controller Setting] and [Ethernet] of GT Designer3
<Connecting to Built-in Ethernet port CPU>
(The following settings are set to the default)
Network No.
PLC No.
IP address
Open system
*1
For the settings when using system devices including a hub
and a transceiver, refer to the following.
23.4.6 Connecting to Built-in Ethernet port CPU
(multiple connection)
*2
These setting items do not exist on the PLC side. However,
the virtual values must be set on the GOT side.
 [Controller Setting] and [Ethernet] of GT
Designer3
Basic setting of MT Works2
Use the default values of the basic setting for the system
configuration above.
(1) Built-in Ethernet Port Setting
Item
192.168.3.39
IP Address
Subnet Mask Pattern
Default Router IP Address
23. ETHERNET CONNECTION
23.4 PLC Side Setting
<GOT>
(The settings other than the
following are set to the default)
Network No.
: 1
PLC No.
: 1
IP address
: 192.168.3.1
Port No.
: 5001
Communication
: UDP (fixed)
format
*1
*2
: 1 (virtual)
*2
: 2 (virtual)
: 192.168.3.39
: MELSOFT connection (fixed)
Setting necessity
Set value
at GOT connection
(Default)
-
-
23 - 53
17
18
19
20
21
22
23
24