Connecting To Ahc2001 Cpu - Mitsubishi Electric GOT2000 Connection Manual

Graphic operation terminal
Hide thumbs Also See for GOT2000:
Table of Contents

Advertisement

3.5.17 Connecting to AHC2001 CPU

Communication settings
Make the communication settings by operating the
Smart Loader Package (SLP-D50/SLP-H21)of the
temperature controller.
Item
*1
9600bps, 19200bps, 38400bps, 57600bps
Transmission speed
0: MODBUS
*2
Communication mode
1: CPL
Data bit
8bits (fixed)
Parity bit
Even (fixed)
Stop bit
1bit (fixed)
*3
Station address
1 to 15
*1
Adjust the settings with GOT settings.
*2
Set this item to 1: CPL.
*3
Select the station address without overlapping with that of
other units.
*4
The station address for AHC2001 ranges from 1 to 127.
However, use station address from 1 to 15, which are the
range for DMC50.
3.5.18 Connecting to AHC2001 SCU
Communication settings
Make the communication settings by operating the
Smart Loader Package (SLP-D50/SLP-H21)of the
temperature controller.
Item
*1
9600bps, 19200bps, 38400bps
Transmission speed
*1
7bits, 8bits
Data bit
*1
0: None, 1:Even, 2: Odd
Parity bit
*1
1bit, 2bits
Stop bit
*2
0: Half duplex, 1: Full duplex
Half duplex/Full duplex
Space sending
0 (fixed)
*3
1 to 30
Protocol setup
*1
Adjust the settings with GOT settings.
*2
Set this item to 0: Half duplex.
*3
Set this item to 2: CPL.
3 - 56
3. CONNECTION TO AZBIL CONTROL EQUIPMENT
3.5 Control Equipment Side Setting
Set value
*4
Set value
3.5.19 Station number setting
Set each station number so that no station number
overlaps.
The station number can be set without regard to the cable
connection order. There is no problem even if station
numbers are not consecutive.
Station
Station
No.3
No.10
GOT
Examples of station number setting
(1) Direct specification
When setting the device, specify the station number of
the control equipment of which data is to be changed.
Model name
SDC40A/40B/40G, SDC15,
SDC25/26, SDC35/36,
SDC20/21, SDC30/31
CML, CMF050, MQV, MPC
PBC201-VN2
SDC45/46
CMS, CMF015, CMC10B
RX
DMC10, DMC50, MVF,
AUR350C, AUR450C, AHC2001
*1
The station number for AHC2001 ranges from 1 to 127.
However, use station numbers from 1 to 15, which are the
range for DMC50.
Station
Station
Station
No.1
No.15
No.6
Specification
range
1 to 127
1 to 126
1 to 120
1 to 99
1 to 32
1 to 15
*1