Connecting To Peripheral I/F (Built-In Ethernet Port Motion Controller Cpu) - Mitsubishi Electric GT1685 Connection Manual

Got1000 series
Table of Contents

Advertisement

8.2.5
Connecting to PERIPHERAL I/F (Built-in Ethernet port Motion Controller
CPU)
PLC
CPU
PLC
Communication
*3
Model name
type
Motion controller CPU
(Q Series)
Q172DCPU-S1
Q173DCPU-S1
Q172DSCPU
Ethernet
Q173DSCPU
Q170MCPU
Q170MSCPU
Q170MSCPU-S1
MR-MQ100
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
*2
When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching
hub and operate in a 10Mbps/100Mbps mixed environment.
For how to check the function version, refer to the following.
*3
When using the PERIPHERAL I/F, set as shown below.
• Use the GT Designer3 Version1.12N or later.
• Select [QnUDE(H)] for [Controller Type] in [Ethernet] of GT Designer3.
*4
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*5
GT14 models compatible with Ethernet connection are only GT1455-QTBDE, GT1450-QMBDE and GT1450-QLBDE.
HINT
HINT
HINT
Direct connection between PERIPHERAL I/F and GOT
The PERIPHERAL I/F and GOT can be directly connected by using a cross cable for the Ethernet connection
cable.
8 - 16
8. ETHERNET CONNECTION
8.2 System Configuration
Q172DCPU-S1
Q173DCPU-S1
Q172DSCPU
Q173DSCPU
Connection cable
Q170MCPU
Q170MSCPU
Q170MSCPU-S1
MR-MQ100
Connection cable
Twisted pair cable
• 10BASE-T
Shielded twisted pair cable (STP) or
unshielded twisted pair cable (UTP):
Category 3, 4, and 5
• 100BASE-TX
Shielded twisted pair cable (STP):
Category 5 and 5e
GT16 User's Manual (Hardware)
For [Ethernet] of GT Designer3, refer to the following.
8.3.3 Ethernet setting
GOT
Maximum
segment
*1
Option device
*4
length
- (Built into GOT)
30m
GT15-J71E71-100
Communication driver
Ethernet(MELSEC),Q17nNC,CRnD-700
GOT
Number of
connectable
Model
equipment
*2
*5
16 GOTs for 1 network

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents