CHAPTER 1 OVERVIEW
• Waveform generator (16-bit timer: 3 channels, 3-phase waveform or dead time)
●
Multi-pulse generator (for DC motor control): 1 channel (not present in MB90465 series)
• 16-bit reload timer: 1 channel (can be used individually in MB90465 series)
• 16-bit PPG timer: 1 channel (not present in MB90465 series)
• Waveform sequencer (includes16-bit timer with buffer and compare clear function) (not present in
MB90465 series)
●
UART: 2 channels
• With full-duplex double buffer (8-bit length)
• Clock asynchronized or clock synchronized transmission (with start and stop bits) can be selectively
used
●
DTP/External interrupt circuit: 8 channels
• A module for starting extended intelligent I/O service (EI
triggered by an external input
●
Delayed interrupt generation module
• Generates an interrupt request for switching tasks
●
8/10-bit A/D converter: 8 channels
• Selectable 8/10-bit resolution
4
2
OS) and generating an external interrupt