CLI User Guide
now 80x20
Welcome to ruggedcom Partition1 (Rev ROX 2.4.0 (2013-01-24 18:20)) RX1510 SN
12110102-0012-0030060017
Temperature +38.5 C (+101.3 F)
root@ruggedcom:~#
CAUTION!
Security hazard – risk of unauthorized access and/or exploitation. Upon accessing service mode
on a device that is connected to a network, make sure SSH is disabled. Failure to disable SSH once
in service mode would allow anyone with remote access to the device and the root password to
access the Linux shell.
Section 2.7.3
Accessing Maintenance Mode
Maintenance mode grants access to the Linux shell.
To access maintenance mode, do the following:
CAUTION!
Configuration hazard – risk of data corruption. Maintenance mode is provided for troubleshooting
purposes and should only be used by Siemens Canada Ltd technicians. As such, this mode is not fully
documented. Misuse of the commands available in this mode can corrupt the operational state of the
device and render it inaccessible.
IMPORTANT!
Changes made to the configuration in this mode will override the current configuration settings (e.g. IP
addresses, VLAN settings, etc.), but are discarded following a system reboot.
In normal mode, type maint-login and press Enter. A password prompt appears.
1.
NOTE
The current maintenance mode password/passphrase is the same as the password/passphrase for
accessing service mode.
Type the current maintenance mode password/passphrase and press Enter.
2.
Example:
ruggedcom# maint-login
Password:
Welcome to ruggedcom Partition2 (Rev ROX 2.4.0 (2013-01-24 18:20)) RX1511 SN R15R-3410-PR061
22:29:20 up 1 day,
Temperature +41.0 C (+105.8 F)
root@ruggedcom:~#
Accessing Maintenance Mode