Siemens RUGGEDCOM ROX II User Manual page 138

Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

Chapter 4
Device Management
show chassis fan-controller status fan
A table or list similar to the following example appears:
ruggedcom# show chassis fan-controller status fan
FAN
FAN
ID
STATE
STATUS
-----------------------
fanA
off
Normal
fanB
standby
Normal
Section 4.14.2
Configuring the Activation Temperature
The individual fan arrays are activated by the fan controller based on the activation temperature. If the ambient
temperature meets or exceeds the set activation temperature, the fan controller activates the fan array that has
been idle the longest.
To set the activation temperature for the fan controller, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Configure the following parameter(s) as required:
Parameter
setpoint-temp { setpoint-temp }
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
3.
Section 4.15
Managing Fixed Modules
This section describes how to manage non-field replaceable modules, such as the control module.
CONTENTS
Section 4.15.1, "Viewing a List of Fixed Module Configurations"
Section 4.15.2, "Adding a Fixed Module Configuration"
Section 4.15.3, "Deleting a Fixed Module Configuration"
Section 4.15.1
Viewing a List of Fixed Module Configurations
To view a list of fixed module configurations, type:
show running-config chassis fixed-modules
92
Synopsis:   A 32-bit unsigned integer between 25 and 85
Default:   50
The temperature above which the fans will be activated. The minimum and maximum
values of this parameter are 25C and 85C.
Description
Configuring the Activation Temperature
RUGGEDCOM ROX II
CLI User Guide