Chapter 14
Network Redundancy
!
!
If no dedicated links have been configured, add dedicated links as needed. For more information, refer to
Section 14.1.10.4, "Adding a Dedicated
Section 14.1.10.4
Adding a Dedicated Link
To add a dedicated link, do the following:
1.
Make sure the CLI is in Configuration mode.
NOTE
RUGGEDCOM ROX II supports up to four dedicated links.
2.
Add a dedicated link by typing:
services conn-sync dedicated-link name
Where name is the name of the dedicated link.
3.
Configure the following parameter(s) as required:
Parameter
interface { interface }
ip { ip }
mcast-ip { mcast-ip }
group { group }
send-buffer { send-buffer }
recv-buffer { recv-buffer }
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
4.
Section 14.1.10.5
Deleting a Dedicated Link
To delete a dedicated link, do the following:
618
Link".
Synopsis:   A string
The interface name of the dedicated link.
Synopsis:   A string 7 to 15 characters long or a string 6 to 40 characters long
The IPv4 or IPv6 address of the dedicated link interface.
Synopsis:   A string 7 to 15 characters long or a string 7 to 39 characters long
Default:   225.0.0.50
The destination IPv4 or IPv6 multicast address of the dedicated link.
Synopsis:   A 16-bit unsigned integer between 1 and 65535
Default:   3780
The multicast group ID of the cluster.
Synopsis:   A 32-bit unsigned integer between 64 and 2560
Default:   1220
The sending socket buffer size in kB.
Synopsis:   A 32-bit unsigned integer between 64 and 2560
Default:   1220
The receiving socket buffer size in kB.
Description
Adding a Dedicated Link
RUGGEDCOM ROX II