Siemens RUGGEDCOM ROX II User Manual page 136

Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

Chapter 4
Device Management
To enable or disable this feature, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Enable or disable the boot time integrity check by typing:
Enable
admin boot-time-firmware-integrity-check
Disable
no admin boot-time-firmware-integrity-check
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
3.
Section 4.13.2
Checking the Firmware Integrity
To check the firmware integrity manually, type:
admin check-integrity
If the integrity check fails, the following message is displayed:
FAILURE. The firmware integrity check has failed. This may indiciate that some operating system files
have been modified or tampered with. For assistance, contact Siemens Customer Support.
Section 4.13.3
Scheduling a Recurring Firmware Integrity Check
Using the RUGGEDCOM ROX II scheduler, the firmware integrity check can be scheduled to run automatically
at a specific time and date, either once or on a recurring schedule. For more information about scheduling the
firmware integrity check, refer to
Section 4.13.4
Viewing the Status of the Firmware Integrity Check
To view the status of the last firmware integrity check, type:
show chassis chassis-status
For example:
ruggedcom# show chassis chassis-status
chassis-status
model
software license
rox release
system serial number
last integrity check
last integrity check result "FAILURE. The firmware integrity check has failed. This may indicate that
some operating system files have been modified or tampered with. For assistance, contact Siemens
Customer Support."
90
Section 5.10, "Scheduling
RX1501
"Layer 3 Security Edition"
"ROX 2.12.0-QA1.9 (2018-01-26 12:58)"
RX1501R-0812-00664
"2018-02-07 14:31"
Jobs".
RUGGEDCOM ROX II
CLI User Guide
Checking the Firmware Integrity

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents