Section 13.5.1
Viewing a List of Event Trackers
To view a list of event trackers, type:
show running-config global tracking
If event trackers have been configured, a table or list similar to the following example appears:
ruggedcom# show running-config global tracking
global
tracking
event host-in-lan-11
target
192.168.11.100
timeout
500
interval 500
fall
3
rise
3
!
!
!
If no event trackers have been configured, add event trackers as needed. For more information, refer to
Section 13.5.3, "Adding an Event
Section 13.5.2
Viewing Event Tracker Statistics
RUGGEDCOM ROX II records statistics for each event tracker.
To view the statistics for an event tracker, type:
show global tracking event statistics
A list similar to the following example appears:
ruggedcom# show global tracking event statistics
ECHO
NAME
ATTEMPTS
-----------------------------------------------------------------
host-in-lan-11
0
Viewing a List of Event Trackers
Tracker".
ECHO
MIN
AVERAGE
REPLIES
RTT
RTT
0
0.0
0.0
STANDARD
MAX
DEVIATION
RTT
RTT
0.0
0.0
Chapter 13