Siemens RUGGEDCOM ROX II User Manual page 139

Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

RUGGEDCOM ROX II
CLI User Guide
If fixed modules have been configured, a table or list similar to the following example appears:
ruggedcom# show running-config chassis fixed-modules | tab
chassis
fixed-modules
fixed-module
SLOT
MODULE TYPE
------------------------------------------------------------
cm
RX5000 Control Module
!
!
If no fixed modules have been configured, add fixed module configurations as needed. For more information,
refer to
Section 4.15.2, "Adding a Fixed Module
Section 4.15.2
Adding a Fixed Module Configuration
To add a configuration for a fixed module, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Add the module by typing:
chassis fixed-modules fixed-module slot
Where:
• slot is the name of the module location
3.
Configure the following parameter(s) as required:
Parameter
module-type { module-type }
partnumber { partnumber }
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
4.
Section 4.15.3
Deleting a Fixed Module Configuration
To delete the configuration for a fixed module, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Delete the configuration for a fixed module by typing:
no chassis fixed-modules fixed-module slot
Where:
• slot is the name of the module location
Adding a Fixed Module Configuration
PARTNUMBER
12-86-0016-001 12-86-0035-001
Configuration".
Synopsis:   A string 1 to 60 characters long
The module type to be used in this slot.
This parameter is mandatory.
Synopsis:   A string 1 to 74 characters long
The part number of the module type in this slot.