Section 14.2
Managing Link Failover Protection
Link failover provides an easily configurable means of raising a backup link upon the failure of a designated main
link. The main and backup links can only be Ethernet.
Link failover can back up to multiple remote locations, managing multiple main-to-backup link relationships.
Link failover can also be used to migrate the default route from the main link to the backup link.
The time after a main link failure to backup link startup, and the time after a main link recovery to backup link
stoppage, are configurable. The link failover function also provides failover status information and a test of the
failover settings.
CONTENTS
Section 14.2.1, "Viewing the Link Failover Log"
Section 14.2.2, "Viewing the Link Failover Status"
Section 14.2.3, "Managing Link Failover Parameters"
Section 14.2.4, "Managing Link Failover Backup Interfaces"
Section 14.2.5, "Managing Link Failover Ping Targets"
Section 14.2.6, "Testing Link Failover"
Section 14.2.7, "Canceling a Link Failover Test"
620
Synopsis:   A string
The conn-sync dedicated link interface name.
Synopsis:   A string
The conn-sync dedicated link status.
Synopsis:   A string
The conn-sync dedicated link role.
Synopsis:   A 64-bit unsigned integer
The number of bytes sent on conn-sync dedicated link.
Synopsis:   A 64-bit unsigned integer
The number of bytes received on conn-sync dedicated link.
Synopsis:   A 64-bit unsigned integer
The number of packets sent on conn-sync dedicated link.
Synopsis:   A 64-bit unsigned integer
The number of packets received on conn-sync dedicated link.
Synopsis:   A 64-bit unsigned integer
The number of errors sent on conn-sync dedicated link.
Synopsis:   A 64-bit unsigned integer
The number of errors received on conn-sync dedicated link.
Description
Managing Link Failover Protection
RUGGEDCOM ROX II