Chapter 16
Traffic Control and Classification
Section 16.1.3.1
Viewing a List of Ingress Source Ports
To view a list of ingress source port for port mirroring, type:
show running-config switch port-mirroring ingress-src
If ingress source ports have been configured, a table or list similar to the following example appears:
ruggedcom# show running-config switch port-mirroring ingress-src
switch port-mirroring
ingress-src lm1 1
!
!
If no ingress source ports have been configured, add ingress source ports as needed. For more information, refer
to
Section 16.1.3.2, "Adding an Ingress Source
Section 16.1.3.2
Adding an Ingress Source Port
To add an ingress source port for port mirroring, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Add the ingress source port by typing:
switch port-mirroring ingress-src slot port
Where:
• slot is the name of the module location
• port is the port number (or a list of ports, if aggregated in a port trunk) for the module
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
3.
Section 16.1.3.3
Deleting an Ingress Source Port
To delete an ingress source port for port mirroring, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Delete the address by typing:
no switch port-mirroring ingress-src slot port
Where:
• slot is the name of the module location
• port is the port number (or a list of ports, if aggregated in a port trunk) for the module
Type commit and press Enter to save the changes, or type revert and press Enter to abort.