CLI User Guide
Section 10.8
Managing Local Host Interfaces
Local host interfaces are required when the UDP transport connection protocol is selected for the raw socket
protocol and when a local host is configured.
CONTENTS
Section 10.8.1, "Viewing a List of Local Host Interfaces"
Section 10.8.2, "Adding a Local Host Interface"
Section 10.8.3, "Deleting a Local Host Interface"
Section 10.8.1
Viewing a List of Local Host Interfaces
To view a list of local host interfaces configured for a serial port using the raw socket protocol, type:
show running-config interface serial slot port protocols rawsocket setrawsocket local-host local-host
interface
Where:
• slot is the name of the module location
• port is the port number (or a list of ports, if aggregated in a port trunk) for the module
• local-host is the local host
If interfaces have been configured, a table or list similar to the following example appears:
ruggedcom# show running-config interface serial lm5 1 protocols rawsocket setrawsocket local-host
224.1.2.1 interface
interface
serial lm5 1
protocols rawsocket
setrawsocket local-host 224.1.2.1
interface ge-4-4
!
!
!
!
!
If no local host interfaces have been configured, add interfaces as needed. For more information, refer to
Section 10.8.2, "Adding a Local Host
Section 10.8.2
Adding a Local Host Interface
NOTE
A maximum of two interfaces are permitted for each local host.
To add a local host interface for a serial port using the raw socket protocol, do the following:
Managing Local Host Interfaces
Interface".