Device Management
.
.
**> sess:9450 read:
<rpc xmlns="urn:ietf:params:xml:ns:netconf:base:1.0" message-id="103">
<validate>
<source>
<running/>
</source>
</validate>
</rpc>
**< sess:9450 write:
<rpc-reply message-id="103" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<ok/>
</rpc-reply>
.
.
.
CAUTION!
Configuration hazard – risk of reduced performance. Enabling diagnostic logging will significantly
affect the performance of RUGGEDCOM ROX II. Only enable diagnostic logging when directed by
Siemens.
To enable or disable the NETCONF Trace log, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Enable or disable the NETCONF Trace log by typing the following commands:
Enable
admin logging diagnostics netconf-trace-log enabled
Disable
no admin logging diagnostics netconf-trace-log enabled
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
3.
Section 4.10.4.5
Enabling/Disabling the XPATH Trace Log
The XPATH trace log records internal events related to XPATH routines that require interaction with an XPATH
component.
CAUTION!
Configuration hazard – risk of reduced performance. Enabling diagnostic logging will significantly
affect the performance of RUGGEDCOM ROX II. Only enable diagnostic logging when directed by
Siemens.
To enable or disable the XPATH Trace log, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Enable or disable the XPATH Trace log by typing the following commands:
Enable
admin logging diagnostics xpath-trace-log enabled
76
CLI User Guide
Enabling/Disabling the XPATH Trace Log
RUGGEDCOM ROX II