CLI User Guide
Alarm Type
Alarm
Chassis
Module Type Mismatch
Chassis
Line Module Removed
Chassis
Line Module Inserted
Security
Firmware Integrity Check Failed
Section 5.7.2
Viewing a List of Active Alarms
To view a list of alarms for a specific alarm type, type:
show admin alarms
A table or list similar to the following example appears:
ruggedcom# show admin alarms | tab
ALARM
SUBSYSTEM
ID
ACTUATORS
---------------------------------------------------------------------------------------------
switch
1
For information on how to clear or acknowledge an active alarm, refer to
Acknowledging
Alarms".
Section 5.7.3
Clearing and Acknowledging Alarms
There are two types of alarms: conditional and non-conditional. Conditional alarms are generated when the
condition is true and cleared when the condition is resolved and the incident is acknowledged by the user.
Non-conditional alarms, however, are simply generated when the event occurs (a notification) and it is the
responsibility of the user to clear the alarm.
An example of a conditional alarm is a link down alarm. When the condition is resolved (i.e. the link comes up),
the LED and alarm relay are both disabled, if the auto-clear option is enabled.
Examples of non-conditional alarms are link up and internal configuration errors.
CONTENTS
Section 5.7.3.1, "Clearing Alarms"
Section 5.7.3.2, "Acknowledging Alarms"
Viewing a List of Active Alarms
EVENT
ID
SEVERITY
DESCRIPTION
1
notice
Link-up on port lm1/8
Description
maximum operating temperature
range of the device.
The configured module type does not
match the detected module type.
The specified line module has either
been removed or lost contact with the
chassis.
A new line module has been inserted
in the specified slot.
The firmware has failed the binary
integrity check, indicating that one
or more operating system files have
been modified or tampered with.
DATE TIME
Wed Feb
Section 5.7.3, "Clearing and
System Administration
Suggested Resolution
Updated the chassis configuration or
install the correct module type.
Inspect the line module.
Contact Siemens Customer Support.
USER ACTIONS
6 16:08:44 2013
clear-or-ack
Chapter 5
none
109