IP Address Assignment
Section 7.1.2
Viewing Statistics for Routable Interfaces
To view statistics for all routable interfaces, type:
show interfaces ip
A table or list similar to the following appears:
ruggedcom# show interfaces ip
interfaces ip dummy0
admin state down
state
down
pointopoint false
receive
bytes
0
packets 0
errors
0
dropped 0
transmit
bytes
0
packets
0
errors
0
dropped
0
collisions 0
interfaces ip fe-cm-1
.
.
.
This table or list displays the following information:
Parameter
admin-state
state
pointopoint
bytes
packets
errors
dropped
212
Synopsis:   { not set, up, down, testing, unknown, dormant, notPresent, lowerLayerDown }
The port's administrative status.
This parameter is mandatory.
Synopsis:   { not set, up, down, testing, unknown, dormant, notPresent, lowerLayerDown }
Shows whether the link is up or down.
This parameter is mandatory.
Synopsis:   { true, false }
The point-to-point link.
This parameter is mandatory.
Synopsis:   A 64-bit unsigned integer
The number of bytes received.
This parameter is mandatory.
Synopsis:   A 64-bit unsigned integer
The number of packets received.
This parameter is mandatory.
Synopsis:   A 32-bit unsigned integer
The number of error packets received.
This parameter is mandatory.
Synopsis:   A 32-bit unsigned integer
The number of packets dropped by the receiving device.