Siemens RUGGEDCOM ROX II User Manual page 770

Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

Chapter 16
Traffic Control and Classification
IP ADDRESS
PORT
-------------------------------
172.30.142.224
6030
!
!
If no collectors have been configured, add collectors as needed. For more information, refer to
"Adding a NetFlow
Collector".
Section 16.4.8.2
Adding a NetFlow Collector
To define a NetFlow collector to which RUGGEDCOM ROX II will send flows, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Add the collector by typing:
NOTE
A single server can host multiple NetFlow collectors, each monitoring a specific UDP port.
services netflow collector address port
Where:
• address is the IPv4 address of the NetFlow collector
• port is the UDP port used by the NetFlow Collector to receive messages
3.
[Optional] Enable the collector so RUGGEDCOM ROX II can forward NetFlow packets to it. For more
information, refer to
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
4.
Section 16.4.8.3
Enabling/Disabling a NetFlow Collector
To enable or disable a NetFlow collector defined in RUGGEDCOM ROX II, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Enable or disable the collector by typing:
Enabling
services netflow collector address port enable
Disabling
no services netflow collector address port enable
Where:
• address is the IPv4 address of the NetFlow collector
• port is the UDP port used by the NetFlow collector to receive messages
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
3.
724
ENABLED
true
Section 16.4.8.3, "Enabling/Disabling a NetFlow
Section 16.4.8.2,
Collector".
Adding a NetFlow Collector
RUGGEDCOM ROX II