RUGGEDCOM ROX II
CLI User Guide
Section 4.18
Managing Routable Ethernet Ports
This section describes how to configure routable Ethernet Ports, including the assignment of VLANs.
CONTENTS
Section 4.18.1, "Viewing a List of Routable Ethernet Ports"
Section 4.18.2, "Configuring a Routable Ethernet Port"
Section 4.18.3, "Managing VLANs for Routable Ethernet Ports"
Section 4.18.1
Viewing a List of Routable Ethernet Ports
To view a list of routable Ethernet ports, type:
show running-config interface eth
A table or list similar to the following example appears:
ruggedcom# show running-config interface eth
interface
eth cm 1
auton
no proxyarp
no on-demand
no alias
lldp
no notify
!
!
!
Section 4.18.2
Configuring a Routable Ethernet Port
To configure a routable Ethernet port, do the following:
1.
Make sure the CLI is in Configuration mode.
Navigate to interface » eth » {interface}, where {interface} is the routable Ethernet port.
2.
3.
Configure the port settings by configuring the following parameter(s):
Parameter
{ slot }
{ port }
enabled
Managing Routable Ethernet Ports
Synopsis:   { { cm, em }{ sm, lm1, lm2, lm3, lm4, lm5, lm6, swport, eth, serport, celport,
wlanport } }
The name of the module location provided on the silkscreen across the top of the device.
Synopsis:   A 32-bit signed integer between 1 and 16
The port number as seen on the front plate silkscreen of the switch (or a list of ports, if
aggregated in a port trunk).
Synopsis:   { true, false }