Siemens RUGGEDCOM ROX II User Manual page 154

Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

Chapter 5
System Administration
Alarm Type
Security
Services
CONTENTS
Section 5.7.1, "Pre-Configured Alarms"
Section 5.7.2, "Viewing a List of Active Alarms"
Section 5.7.3, "Clearing and Acknowledging Alarms"
Section 5.7.4, "Configuring an Alarm"
Section 5.7.1
Pre-Configured Alarms
RUGGEDCOM ROX II is equipped with a series of pre-configured alarms designed to monitor and protect the
device.
Alarm Type
Alarm
Admin
Featurekey mismatch
Admin
Featurekey partial mismatch
Chassis
PM1 bad supply
Chassis
PM2 bad supply
Chassis
PM1 MOV protection bad
Chassis
PM2 MOV protection bad
Chassis
Real-time clock battery low
Chassis
LM Watchdog Failure
Chassis
Fan-Controller Hardware Failure (For
MX5000RE Only)
Chassis
Fan-Controller Overtemp (For
MX5000RE Only)
108
Description
Security alarms are for certificate expiry events. This includes warnings 30 days before a certificate is set to
expire and when an expired certificate is installed.
Service alarms are for events related to RUGGEDCOM ROX II services, such as time services, link failover,
Dynamic Domain Name Server (DNS) etc.
Description
The featurekey does not match the
serial numbers for the control module
and backplane hardware.
The featurekey does not match the
serial number for either the control
module or backplane hardware.
Input power to the power module is
outside nominal operating range.
Input power to the power module is
outside nominal operating range.
The Metal Oxide Varistor (MOV)
protection component within the PM1
power module is damaged.
The Metal Oxide Varistor (MOV)
protection component within the PM2
power module is damaged.
The Real-Time Clock (RTC) battery in
the control module is depleted.
The specified line module has stopped
sending its heartbeat message to the
control module.
The fan tray is damaged. One or more
fan trays may stop spinning.
The ambient temperature within the
RuggedEnclosure has exceeded the
RUGGEDCOM ROX II
CLI User Guide
Suggested Resolution
Move the featurekey to the correct
device with the matching hardware or
request an updated key from Siemens
Customer Support.
Move the featurekey to the correct
device with the matching hardware or
request an updated key from Siemens
Customer Support.
Make sure the input power operating
range meets the device requirements.
Make sure the input power operating
range meets the device requirements.
Contact Siemens Customer Support to
return the power module.
Contact Siemens Customer Support to
return the power module.
Contact Siemens Customer Support to
return the device for repair.
Inspect the line module to make sure
it is functioning properly.
Contact Siemens Customer Support to
return the fan module.
Power down the device until the
ambient temperature has cooled.
Pre-Configured Alarms