Siemens RUGGEDCOM ROX II User Manual page 670

Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

Chapter 14
Network Redundancy
Parameter
main-up-timeout { main-up-timeout }
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
4.
Section 14.2.3.3
Deleting a Link Failover Parameter
To delete a link failover parameter, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Delete the parameter by typing:
no services link-failover interface
Where:
• interface is the name of the interface
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
3.
Section 14.2.4
Managing Link Failover Backup Interfaces
A backup interface is the interface to which link failover switches when the main interface is determined to be
down. You can add up to three backup interfaces to each link failover configuration.
CONTENTS
Section 14.2.4.1, "Viewing a List of Link Failover Backup Interfaces"
Section 14.2.4.2, "Adding a Link Failover Backup Interface"
Section 14.2.4.3, "Deleting a Link Failover Backup Interface"
Section 14.2.4.1
Viewing a List of Link Failover Backup Interfaces
To view a list of link failover backup interfaces, type:
show running-config services link-failover interface backup
Where:
• interface is the name of the interface
If backup interfaces have been configured, a table or list similar to the following example appears:
ruggedcom# show running-config services link-failover switch.0001 backup
624
The delay time, in seconds, that the main trunk is down before starting the backup trunk.
Synopsis:   A 32-bit signed integer between 0 and 65536
Default:   60
The delay time, in seconds, to confirm that the main trunk is up (returned to service)
before stopping the backup trunk.